USBKEY 0068
	- Updated Installation.txt

USBKEY 0065
	- [Profishark 10G/10G+] Add support for 1G SFP
	- [Profishark 10G/10G+] New hardware revision supports 10GBASE-T SFP+
	- [Profishark 10G/10G+] Fix issue with filters

USBKEY 0063
	- [Profishark 100M Blue] Add support for USB 2.0
	- Add restart device button
	- Fix issue with memory capture
	- Avoid internal reset when starting/stopping direct capture

USBKEY 0061 - 03/04/2018
	- Profishark 1G Black: Fix capture corruption

USBKEY 0060 - 29/03/2018
	- Profishark 1G: Fix capture corruption

USBKEY 0059 - 08/03/2018
	- Profishark_1.3.58.exe: Include firmware in installer.
	- Automatic new firmware detection and update.
	- Synology NAS support first release.

USBKEY 0057 - 27/11/2017
	- 1G+ 0.2.3.13.0110.img: fix capture corruption
	- 1G 0.2.3.11.0110.img: improve stability
	- 10G+ 0.2.3.22.0210.img: first firmware release

USBKEY 0055 - 09/11/2017
	- Installation.txt: updated Linux installation information
	- New Linux drivers binaries

USBKEY 0054 - 18/10/2017
	- 10G 0.2.3.15.0005.img: Configurable slicing option
	- Profishark_1.3.49.exe: fix bugs

USBKEY 0053 - 09/10/2017
	- New Linux drivers binaries
	- 10G+ Firmware: 0.2.3.14.0004.img
	- Updated ProfiShark 1G/1G+ user manual to v3.0.3
	- Updated ProfiShark 10G user manual to v1.0.6

USBKEY 0051 - 28/04/2017
	- New Linux drivers.

USBKEY 0050 - 06/04/2017
	- 1G(blue) 0.2.3.7.0108.img: improve stability.

USBKEY 0049 - 30/03/2017
	- CLI support for DPI settings and features management (including slicing)
	- 10G 0.2.3.11.0005.img: Improve noise imunity (PRBS traffic),
	- added original frame length information (direct capture, Wireshark capture with dissector), fix out-of-order packets, fix capture corruption,
	- Statistics counters: IP field now detects source or destination. 

USBKEY 0048 - 27/03/2017
	- 1G(blue) 0.2.3.7.0107.img: fix USB 2.0 mode, added original frame length information to capture (direct capture, Wireshark capture with dissector).

USBKEY 0047 - 15/03/2017
	- New Linux drivers binaries
	- Added ProfiShark 10G user manual v1.0.5
	- Updated ProfiShark 1G/1G+ user manual to v3.0.2:
	- - Page 22: added precisions about the ProfiShark dissector

USBKEY 0046 - 06/03/2017
	- 1G(blue) 0.2.3.5.0106.img: Fix capture corruption 
	- 1G(black) 0.2.3.5.0012.img: Fix capture corruption 

USBKEY 0045 - 01/03/2017
	- 1G(blue) 0.2.3.5.0105.img: Improve USB performances, fix out-of-order packets, new dissector 
	- 1G(black) 0.2.3.5.0011.img: Improve USB performances, fix out-of-order packets
	- 1G+ 0.2.3.10.0109.img: Improve USB performances, fix out-of-order packets
	- Linux API improvement

USBKEY 0043 - 07/02/2017
	- 1G+ HW0107: Improve stability, new live capture timestamp format.
	- Dissector for 1G+ HW0107 and future 1G HW fimwares, unified dissector with 10G/10G+.
	- CentOS driver and manager.
	- Linux driver 1.9.1: Fixed a memory overflow.
	- profishark-1g-cmd_1.2-1: New version

USBKEY 0041
	- 1G (black label) 0.2.3.5.0010.img
	- 1G (blue label) 0.2.3.5.0103.img
	- 1G+ 0.2.3.10.0105.img
	- - Improve stability.

USBKEY 0040
	- profishark-linux-driver_1.7.0, profishark-manager_2.4.2-1:
	- - Fix performance issue

USBKEY 0039
	- Profishark_1.3.29.exe:
	- - API improvement

USBKEY 0038
	- Profishark_1.3.26.exe:
	- - Improve performance and stability.
	- ProfiShark Wireshark dissector (Windows):
	- - Support for Wireshark 2.2
	- profishark-linux-driver_1.4.7-1.zip:
	- - API on Linux

USBKEY 0037
	- Profishark 1G+ 0.2.3.9.0105.img:
	- - Improve performance and stability.

USBKEY 0035
	- Updated installation instructions. 

USBKEY 0034
	- - Profishark 10G 0.2.3.11.0004.img
	- - Profishark 1G+ 0.2.3.9.0102.img
	- - Profishark 1G (blue label) 0.2.3.4.0103.img
	- - Profishark 1G (black label) 0.2.3.4.0010.img
	- - Profishark Manager Profishark_1.3.24.exe
	- Added the USB connection speed under feature tab.

USBKEY 0033
	- - Profishark 10G 0.2.3.10.0004.img: 
	- Fix timestamp bug,
	- Fix minor bugs.

USBKEY 0032
	- - Profishark_1.3.20.exe: Windows 10 support

USBKEY 0031
	- - updated manual to v3.0

USBKEY 0030
	- - Profishark 10G: fix packet slicing, increase packet buffer to 1MB
	- - Profishark_1.3.19.exe: fix memory leak

USBKEY 0029
	- - Profishark 10G: fix timestamp in live capture
	- - dissector 1.6: add Profishark 10G timestamp mode

USBKEY 0028
	- - Profishark 1G+ RTC PPS output 

USBKEY 0027
	- - added Profishark 10G

USBKEY 0026
	- - profishark-1g-manager_2.3.4.zip: fix default value of "Maximum Capture File Size(MB)"

USBKEY 0025
	- - Profishark_1.3.15.exe: fix update
	- - 2.3.3.0010.img: fix update


USBKEY 0024
	- - Profishark_1.3.14.exe: fix update
	- - 2.3.2.0010.img: fix update

USBKEY 0023
	- - added the 1G (black label) firmware
	- - updated manual to v2.5

USBKEY 0022
	- profishark-1g-linux-driver-1.4.5.zip, profishark-1g-manager_2.3.3.zip
	- - fix Maximum Capture File Size
	- - fix file name extension in direct capture
	- - fix date and time in filename
	- - low latency kernel drivers
	- Profishark_1.3.11.exe
	- - new Profishark versions supported

	- Profishark 1G+ firmware 0.2.3.5.0102.img

USBKEY 0021
	- profishark-1g-linux-driver-1.4.4.zip
	- - fix Maximum Capture File Size

USBKEY 0020
	- profishark-1g-manager_2.3.2-1.zip
	- - fix Maximum Capture File Size

USBKEY 0019
	- profishark-1g-manager_2.3.1-1.zip, profishark-1g-linux-driver_1.4.3.zip, 
	- - Correction of last buffer retention in SPAN mode,
	- - fix instability makin,

USBKEY 0018
	- profishark-1g-manager_2.3.0-1.zip, profishark-1g-linux-driver_1.4.2.zip, 
	- - buggy version

USBKEY 0017
	- ProfiShark_1.3.2.exe, 0.2.3.2.0103.img, 
	- - Correction of last buffer retention in SPAN mode,
	- - fix instability,

USBKEY 0016
	- Dissector 1.15:
	- - Support for Wirshark 2.x
	- - Correction of timestamp rounding

USBKEY 0015
	- Profishark-1G_1.2.18:
	- - New Profishark supported.

USBKEY 0013
	- 0.2.2.5-0010.img:
	- - fix transmission corruption.

USBKEY 0012
	- Profishark Manual v2.3:
	- - Profitap HQ address changed.

USBKEY 0011
	- Profishark-1G_1.2.9:
	- - fix bug in command line tool.

USBKEY 0010
	- 0.2.2.5-0009.img, Profishark-1G_1.2.5:
	- - fix direct capture file corruption.

USBKEY 0009
	- - Change firmware version notation
	- 0.2.2.2-0008.img, Profishark-1G_1.2.2:
	- - fix direct capture file corruption, caused by ZLP correction.
	- - fix hardware drops, caused by ZLP correction.

USBKEY 0008
	- Wrong version

USBKEY 0007

	- ProfiShark-1G_1.1.8.exe, HW0008.img:
	- - fix the keyboard/mouse bug caused by ZLP packet.

USBKEY 0006

	- ProfiShark-1G_1.1.7.exe:
	- - Added a workaround for a .NET bug in the charting component triggered by sudden changes in bandwidth usage.

USBKEY 0005

	- ProfiShark-1G_1.1.6.exe:
	- - Added support for new products
	- - Fixed leaked memory when the Profishark is removed while in direct copy mode
	- - Fixed incorrect  IO Request return status for some requests.
	- - Fixed regression allowing to write outside the direct capture filename buffer
	- - Unload the control device when no Profishark is present. This allows to update the driver without having to reboot.
	- - Kernel crash after running for some time on certain configurations
	- When capturing packets, after some time the kernel may crash on some configurations
	- Some memory from internal buffer was reused after being freed in a rare case.

USBKEY 0004

	- Dissector 1.13:
	- -new version supporting Profishark 1G and 100M.

USBKEY 0003

	- ProfiShark-1G_1.1.2.exe:
	- -Exception when drawing charts
	- When drawing charts showing huge and sudden changes in bandwidth usage, the software may raise an exception and exit unexpectedly when the Bandwidth usage checkbox is checked.
	- This was due to a bug in the charting component trying to draw outside of a GDI surface when displaying very steep lines.
	- This has been fixed by rescaling the charts before drawing it.

	- ProfiShark 1G Manual v2.2.pdf:
	- Logo fixed.

USBKEY 0002

	- ProfiShark 1G Manual v2.1.pdf:
	- Profitap HQ address changed.

USBKEY 0001

	- ProfiShark-1G_1.1.1.exe:
	- -Direct capture file count was not enforced.
	- Due to an error in the communication protocol between the Profishark Manager software and the system driver, the maximum file count for direct capture was not being enforced.
	- The communication protocol has been fixed to allow the Profishark Manager to set the maximum file count in direct capture mode.

	- HW0007.img:
	- -CRC error packets was counted twice.

USBKEY 0000

	- ProfiShark-1G_1.1.0.exe:
	- -Communication problems between the Profishark Manager and the Profishark-1G device with some firewalls
	- The communication protocol between the manager and the driver has been totally reworked to be compatible with recent firewalls and antivirus software.
	- -Support for multiple Profishark-1G devices
	- -Visual changes in Profishark Manager (counters layout and charts)
	- -The setup utility now updates the software without asking the user to remove old versions manually.
	- -Current cache usage in Profishark Manager sometimes incorrectly shows huge values.